
Coupled pipe, for split systems and heat pumps. Suitable for R407/R410/R32 gas
Pre-insulated coupled copper tube produced in compliance with current regulations and in reference to the Ministerial Decree. 37/2008 and compliant with energy saving regulations such as Law no. 10/91, the Presidential Decree. 412/93, Legislative Decree 19 August 2005, n° 192 and Legislative Decree 29 December 2006, n° 311.
The copper pipe complies with UNI EN 12735-1:2020 “round copper pipes for air conditioning and refrigeration systems” and is made up of a CU-DHP alloy, annealed in phosphorus deoxidized rolls, with a minimum copper content of 99.9% and phosphorus content between 0.015% and 0.040%.
Based on the above elements, the product copper pipes “BIPOLAR” they are suitable for the passage of refrigerant gases such as R407/C, R410/A and R 32.
Covered with a low density closed cell expanded polyethylene sheath, of suitable thickness, finished with an extruded external film, made up of white, embossed PE-LD, which gives the product further mechanical protection as well as an aesthetic finish, it is non-toxic, odorless and free from chlorofluorocarbons (CFCs).
Bipolar
The sheath
The insulating sheath produced by ISOCLIMA has obtained the fire reaction class BL-s1,d0 in compliance with the European Standard UNI EN 13501-1 as the best fire resistance for expanded insulating materials.
Its main characteristics are: excellent elasticity, flexibility and high resistance to the diffusion of water vapor, which allows avoiding the formation of condensation on the surface of the pipe, when fluids with temperatures lower than room temperature are transferred inside the pipe.
The applications
BIPOLAR by ISOCLIMA finds its best use in the transport of refrigerant gases (split or VRV systems).

Technical characteristics of expanded PE insulation
| Spessore parete tubo di rame Copper pipe wall thickness |
0,80 – 1 mm |
| Spessore isolamento* Insulation thickness* |
6,5 – 10 mm * |
| Temperature d’impiego Operating temperature range |
-80°C + 98°C |
| Coeff. Dispersione vapore acqueo Coeff. Of water vapour dispersion |
5901 µ |
| Conducibilità termica Thermal conductivity |
0.040 W·m⁻¹·K⁻¹ |
| Densità isolamento Insulation density |
30 KG/m³ |
| Resistenza al fuoco Fire resistance |
BL s1, d0 secondo la UNI EN 13501-1 |
| Confezione Packaging |
Rotoli confezionati singolarmente con film trasparente ad ulteriore protezione. Rotoli da 25 metri o 50 metri. Comes in single coils wrapped in clear film for added protection. 25 and 50 metre coils. |
| Dimensioni del tubo di rame nudo (mm) Bare copper pipe dimentions (mm) |
1/4×0,8 – 3/8×0,8 | 1/4×0,8 – 1/2×0,8 | 1/4×0,8 – 5/8×1 | 3/8×0,8 – 1/2×0,8 | 3/8×0,8 – 5/8×1 | 3/8×0,8 – 3/4×1 | 1/2×0,8 – 3/4×1 |
| Spessore della guaina isolante (mm)* Thickness of insulating sheath (mm)* |
6,5 * | 6,5-10 * | 6,5-10 * | 7-10 * | 7-10 * | 7-10 * | 10-10 * |
| Pressione di scoppio nominale (MPa) Nominal bursting pressure (MPa) |
56,54 | 56,54-28,27 | 56,54-28,28 | 37,71-28,27 | 37,71-28,28 | 37,71-23,55 | 28,27-23,55 |
| Pressione di esercizio nominale (ASTM B 111 M) (MPa) Nominal working pressure (ASTM B 111 M) (MPa) |
14,14 | 14,14-7,07 | 14,14-7,07 | 9,43-7,07 | 9,43-7,07 | 9,43-5,89 | 7,07-5,89 |
* The thicknesses applied are standard, however it is recommended to consult your designer to examine any specific needs related to the installation conditions as required by UNI EN 12241.
* The thicknesses applied are standard, however it is suggested that you consult your project designer to examine any specific requirements related to installation conditions as required by UNI EN 12241.




